Prestressed Concrete Flexural Design
Double-Tee Sections | PCI Design Handbook | US Customary Units
Project Information
Hover over any input field for recommended limits |
Modulus of elasticity of prestressing strands is taken as 28,500 ksi
Section Geometry
1
Span Length (L)
ft
2
Total Depth (h)
in
3
Flange Width (bf)
ft
4
Flange Thickness (hf)
in
5
Top Width — Each Web (bw₀)
in
6
Bottom Width — Each Web (bw₁)
in
Topping
7
Composite Topping?
8
Topping Thickness (hₜₒₚ)
in
Material Properties & Exposure
9
f'ci — Precast at Release
ksi
10
f'c — Precast
ksi
11
f'cₜₒₚ — Topping
ksi
12
Concrete Exposure
13
Severe / Corrosive Environment?
14
Max Aggregate Size
Strand Layout
15
CG of Strand Group — Bottom to CG at Support
in
16
Extreme Strand Layer — Bottom to CG at Support
in
17
CG of Strand Group — Bottom to CG at Midspan
in
18
Extreme Strand Layer — Bottom to CG at Midspan
in
19
Strand Diameter (db)
in
20
Total Strand Area (Aₚₛ)
in²
Strand Material & Prestress
21
Tensile Strength (fₚᵤ)
22
Initial Prestress Ratio (fₚᵢ/fₚᵤ)
23
Immediate Prestress Loss
%
24
Total Prestress Loss
%
Density & Loading
25
Density — Precast Member
lb/ft³
26
Density — Topping
lb/ft³
27
Superimposed Dead Load?
28
Superimposed Dead Load (w_sd)
lb/ft²
Results
Click Calculate to see results.
Camber Progression Timeline
At Release
—
in
At Erection
—
in
Erection + DL
—
in
Final + DL
—
in
Final + DL+LL
—
in
Camber Summary
Section Illustration — Double-Tee
Camber & Deflection Diagram
PCI Design Notes & Key Checks
📐 Flexural Strength Check
The design requires:
φMn ≥ Mu
where φ = 0.9 for flexure and Mu is the factored moment demand. The ultimate capacity φMn must exceed all load combinations per ACI 318.
φMn ≥ Mu
where φ = 0.9 for flexure and Mu is the factored moment demand. The ultimate capacity φMn must exceed all load combinations per ACI 318.
📏 Span-to-Depth Ratio
PCI recommends:
L/h ≤ 30 to 40
for double-tee members. Shallower sections may require closer strand spacing or higher prestress levels.
L/h ≤ 30 to 40
for double-tee members. Shallower sections may require closer strand spacing or higher prestress levels.
⚡ Prestress Losses
Typical total losses:
15% – 25% of initial prestress
Include elastic shortening, creep, shrinkage, and relaxation per PCI Design Handbook Chapter 4.
15% – 25% of initial prestress
Include elastic shortening, creep, shrinkage, and relaxation per PCI Design Handbook Chapter 4.
🔍 Transfer Length
Per ACI 318:
lt = 60 · db
The transfer length must be considered when checking stresses at the end regions of the member.
lt = 60 · db
The transfer length must be considered when checking stresses at the end regions of the member.