Prestressed Concrete Flexural Design

Double-Tee Sections  |  PCI Design Handbook  |  US Customary Units

Project Information
Hover over any input field for recommended limits  |  Modulus of elasticity of prestressing strands is taken as 28,500 ksi
Section Geometry
1 Span Length (L) ft
2 Total Depth (h) in
3 Flange Width (bf) ft
4 Flange Thickness (hf) in
5 Top Width — Each Web (bw₀) in
6 Bottom Width — Each Web (bw₁) in
Topping
7 Composite Topping?
8 Topping Thickness (hₜₒₚ) in
Material Properties & Exposure
9 f'ci — Precast at Release ksi
10 f'c — Precast ksi
11 f'cₜₒₚ — Topping ksi
12 Concrete Exposure
13 Severe / Corrosive Environment?
14 Max Aggregate Size
Strand Layout
15 CG of Strand Group — Bottom to CG at Support in
16 Extreme Strand Layer — Bottom to CG at Support in
17 CG of Strand Group — Bottom to CG at Midspan in
18 Extreme Strand Layer — Bottom to CG at Midspan in
19 Strand Diameter (db) in
20 Total Strand Area (Aₚₛ) in²
Strand Material & Prestress
21 Tensile Strength (fₚᵤ)
22 Initial Prestress Ratio (fₚᵢ/fₚᵤ)
23 Immediate Prestress Loss %
24 Total Prestress Loss %
Density & Loading
25 Density — Precast Member lb/ft³
26 Density — Topping lb/ft³
27 Superimposed Dead Load?
28 Superimposed Dead Load (w_sd) lb/ft²
Results
Click Calculate to see results.
Camber Progression Timeline
At Release
—
in
At Erection
—
in
Erection + DL
—
in
Final + DL
—
in
Final + DL+LL
—
in
Camber Summary
Section Illustration — Double-Tee
bf (flange width) h (depth) hf ● Prestressing Strands Double-Tee Cross Section — PCI Design Handbook
Camber & Deflection Diagram
Camber (Positive) +Δ Prestress > Gravity Load Deflection (Negative) -Δ Gravity Load > Prestress PCI Design Handbook — Camber multipliers applied per Table 4.8.3
PCI Design Notes & Key Checks
📐 Flexural Strength Check
The design requires:
φMn ≥ Mu
where φ = 0.9 for flexure and Mu is the factored moment demand. The ultimate capacity φMn must exceed all load combinations per ACI 318.
📏 Span-to-Depth Ratio
PCI recommends:
L/h ≤ 30 to 40
for double-tee members. Shallower sections may require closer strand spacing or higher prestress levels.
⚡ Prestress Losses
Typical total losses:
15% – 25% of initial prestress
Include elastic shortening, creep, shrinkage, and relaxation per PCI Design Handbook Chapter 4.
🔍 Transfer Length
Per ACI 318:
lt = 60 · db
The transfer length must be considered when checking stresses at the end regions of the member.